- expose DEFAULT_MAX_PAYLOAD_BYTES; an inbound frame over the cap now reports its
declared byte size, message type and the effective limit, recovered by walking
the buffered frame stream so the number is right when a chunk carries several
frames, the oversized header spans chunks, or control frames are interleaved;
when the walk cannot reach a verdict the error names the cap without a size
- truncate close reasons to the RFC 6455 control-frame room on a UTF-8 boundary
(an over-long reason previously produced an invalid control frame)
- add optional maxPayloadBytes (default 100 MiB unchanged) to the three adapters
that read WebSocket frames: wsServers, wsClients and httpServers with
enableWebSocket. httpClients rejects the field because it has no WebSocket
transport, and the value is part of the binding signature so a change rebinds
the transport instead of being saved without taking effect
- keep the existing 1009 log lines and append the actionable hint instead of
replacing the template
- WebUI field (including httpServers once the embedded listener is on) and README
docs for the 100 MiB => ~445 s (7:26) inline PCM consequence